Call us now on: 01242 820 199

Three CHambers Mag Meters

Magnetic flow meters are reliant on the pipe running full to provide accurate flow data. An early solution was to relay the pipe work with a ‘Swan Neck’ arrangement to generate the full conditions and then bury the meter. This solution has lead to problems with verification, entrained air and settlement clogging the pipe. There were even occasions where burying the meter has disguised that the pipe is not running full.

The three chamber  system consists of;  a down chamber, which is sized to allow air to be released, a middle inspection chamber, where the meter is fitted and a clamp on meter can be installed, and up chamber where settlement takes place. The system provides easy access for the inspection and verification and can be maintained by sucking out the settlement in the up chamber and jetting the pipework.

This system is now the preferred method for installing Mag meters in Severn Trent and has been used in their recent remedial programme. The system can be designed in standard sizes which has simplified costings and installation for the main Contractor.